The service consists of carrying out fire resistance tests on vertical and horizontal non-loaded separation elements, on doors, and all fire reaction tests provided for by the Ministerial Decree of 26 June 1984 of the Italian Ministry of the Interior, and the EN 13501-1 standard.
In addition, the laboratory performs fire reaction tests on materials and components for railway vehicles.
Details of the test
- Pedestrian doors, industrial, commercial doors, garage doors and opening windows - Product standard, performance characteristics - Fire resistance and / or smoke control characteristics EN 16034 par 5.3: 2014
- Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows UNI EN 1634-1 + EC1: 2018
- Fire resistance tests - General requirements UNI EN 1363-1: 2012
- Fire resistance tests - Alternative and additional procedures UNI EN 1363-2: 2001
- Fire resistance tests for non-load-bearing elements - Walls UNI EN 1364-1: 2015
- Fire resistance tests for non-load-bearing elements - Curtain walling UNI EN 1364-3: 2014 (unaccredited)
- Fire resistance tests for door and shutter assemblies, openable windows and elements of building hardware – Part 2: Fire resistance test for elements of building hardware UNI EN 1634-2: 2009 (unaccredited)
- Fire resistance tests for door and shutter assemblies, openable windows and elements of building hardware – Part 3: Smoke control test for door and shutter assemblies UNI EN 1634-3: 2005 (unaccredited)
- Non-combustibility test UNI EN ISO 1182: 2010
- Determination of organic content UNI EN 13820: 2004 (unaccredited)
- Reaction to fire by applying a small flame UNI 8456: 1987
- Reaction to fire by applying a small flame UNI 8457: 1987
- Reaction to fire of material hit by flame with radiant heating UNI 9174: 1987 (unaccredited)
- Reaction to fire of upholstered furniture by applying a small flame UNI 9175: 2010 (unaccredited)
- Reaction to fire tests – Spread of flame – Part 2: Lateral spread on building and transport products in vertical configuration ISO 5658-2: 2006/Amd 1:2011
- Determination of optical density by a single chamber test UNI EN ISO 5659-2: 2017 (unaccredited)
- Reaction to fire tests for building products - Building products excluding floorings exposed to thermal attack by a single burning item UNI EN 13823: 2014 (unaccredited)
- Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source UNI EN ISO 9239-1: 2010 (unaccredited)
- Reaction to fire tests - Ignitability of building products subjected to direct impingement of flame - Part 2: Singleflame source test UNI EN ISO 11925-2: 2010 EC 1:2011
- Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components UNI CEI EN 45545-2: 2015 (unaccredited)
- Railway applications - Fire protection on railway vehicles - Part 3: Fire resistance requirements for fire barriers UNI CEI EN 45545-3: 2013 (unaccredited test).
Why RINA?
Our laboratory, operating since 1965, is considered to be one of the most authoritative for fire resistance and reaction testing.